Epson M-150 Series

Epson M-150 Series

Impact Mini Printers

Ultra-compact and very reliable



Impact Mini Printers

PRINTER
PRINTING METHOD Shuttle impact dot matrix
PRINTING FORMAT
FONT 5 x 7
COLUMN CAPACITY M-150II: 16 columns
M-160: 24 columns
M-163: 32 columns
M-164: 40 columns
CHARACTER SIZE M-150II: 1.8 (W) x 2.5 (H)mm
M-160: 1.7 (W) x 2.4 (H)mm
M-163: 1.3 (W) x 2.4 (H)mm
M-164: 1.1 (W) x 2.4 (H)mm
LINE SPACING M-150II: 3.5mm (For a 5 x 7 font and 3 dots per line paper feed)
M-160:/M-163/M-164: 3.3mm (For a 5 x 7 font and 3 dots per line paper feed)
COLUMN SPACING M-150II: 2.1mm
M-160: 2.0mm
M-163: 1.5mm
M-164: 1.2mm
NUMBER OF TOTAL DOTS M-150II: 96 dots / line
M-160: 144 dots / line
M-163: 192 dots / line
M-164: 240 dots / line
PRINTING SPEED M-150II: 1.0 line / sec.
M-160: 0.7 line / sec.
M-163: 0.5 line / sec.
M-164: 0.4 line / sec.
PRINTHEAD
TERMINCAL VOLTAGE 3.0 to 5.0 VDC
PEAK CURRENT Approx. 3 A / solenoid
MOTOR
TERMINAL VOLTAGE 3.8 to 5.0 VDC
MEAN CURRENT M-150II: Approx. 0.17 A
M-160/M-163/M-164: Approx. 0.2 A
PAPER
SIMENSIONS M-150II: 44.5 ± 0.5mm (W) x dia. 50mm max.
M-160/M-163/M-164: 57.5 ± 0.5mm (W) x dia. 50mm max.
TOTAL THICKNESS 0.07mm
COPY CAPABILITY Original + one copy
RIBBON CASSETTE M-150II: ERC-05
M-160/M-163/M-164: ERC-09/22
AMBIENT TEMPERATURE 0° to 50°C (operating)
RELIABILITY
MECHANISM (MCBF) M-150II: 0.5 x 106 lines
M-160/M-163/M-164: 0.4 x 106 lines
PRINTHEAD LIFE M-150II: 0.5 x 106 lines
M-160/M-163/M-164: 0.4 x 106 lines
OVERALL DIMENSIONS M-150II: 73.2mm (W) x 42.6mm (D) x 12.8mm (H)
M-160/M-163/M-164: 91.0mm (W) x 42.6mm (D) x 12.8mm (H)
WEIGHT M-150II: Approx. 60 g
M-160/M-163/M-164: Approx. 75 g

Usage Conditions
Epson products are designed and made to give highly reliable use and long life when used according to its specifications. With any system, product or device used in situations where human life may be involved or at risk, Epson advises that you should take all necessary steps to ensure the suitability of your Epson product for inclusion in your system, and recommends that you include fail-safe procedures and redundancy support or backup equipment in your system, to maintain the maximum safety margin and optimum system reliability.